Engineering Disciplines — SCADA + SECURITY

SCADA + Security

FrameAI SCADA + Security generates production-ready instrumentation, control, and physical security documentation per IEC 62443-3-3 (SL-1–4 zones), ISA-5.1 (instrument symbols), EN 54-14 (fire detection), EN 50132 (CCTV coverage), EN 60839-11 (access control), and EN 50131 (intrusion zoning). From your P&ID markup and floor plan, get loop diagrams, I/O schedules, CCTV coverage analysis, access control matrices, and intrusion detection specifications — without outsourcing to a controls engineer.

FrameAI offers all disciplines as individual plans or bundled in cost-effective packages. View pricing →

🛡
See It In Action
IEC 62443-3-3 zone/conduit topology builder, cybersecurity assessment, CCTV FOV calculator — all free, no signup required.
Try network topology builder →
FrameAI vs Junior Engineer — SCADA + Security
Task Junior engineer FrameAI
P&ID tag extraction → ISA-5.1 list 4–6 h < 2 min
Loop diagram generation (per loop) 1–2 h < 30 s
I/O tag register (100-point system) 4–8 h < 3 min
Alarm rationalization EEMUA 191 1–2 h per alarm instant
IEC 62443 zone/conduit topology 3–4 h < 2 min
Cause-and-effect matrix 6–12 h < 5 min
Control narrative → ladder logic 2–4 h < 2 min
Floor plan → CCTV camera placement 3–5 h < 2 min
EN 50132-7 pixel density analysis (per camera) 30–60 min instant
NVR storage & bandwidth model 1–2 h instant
Access control door schedule 2–4 h < 1 min
EN 50131 intrusion detection zoning 2–4 h < 2 min
Risk assessment (EN 50131 Grade) 4–8 h < 3 min
Cable schedule (cameras + readers + detectors) 3–6 h < 2 min
Worked Examples
"I/O schedule generated: 128 tags, 64 DI / 32 DO / 24 AI / 8 AO. Cabinet allocation: MCC-01 (72 pts), JB-02 (56 pts). Marshalling schedule included — ready for panel builder."
P&ID → I/O register output
Try network topology builder →
"Alarm rationalization complete: 340 alarms → 147 high priority, 118 medium, 75 low. 42 nuisance alarms suppressed (EEMUA 191 §4.3). Rationalization report exported."
EEMUA 191 alarm rationalization output
Try IEC 62443 assessment →
"CCTV layout: 24 cameras (16× 2MP varifocal, 8× 4MP PTZ). Coverage: 94% of floor area ≥ 125 PPF (identification grade). NVR storage: 28 TB @ 30-day retention, H.265 compression."
EN 50132-7 CCTV coverage analysis output
Try CCTV coverage calculator →
"Access control: 18 doors, 3 access levels, dual-factor on server room (card + PIN, EN 60839-11 §5.4). UPS: 1.2 kVA for 4-hour standby. Cable schedule: 1.8 km total wiring."
EN 60839-11 access control specification
Try security assessment →
Key Capabilities
IEC 62443-3-3 zone/conduit network topology SVG — SL-1 to SL-4 zones, ICS components, bus arrows
IEC 62443-2-1 cybersecurity assessment — 32 questions, 8 domains, maturity score 0–100
ISA-5.1 loop diagrams — instrument bubbles, 4–20 mA/HART/Modbus signal lines, termination schedules
I/O tag register export (Excel + PDF) — tag, type, range, alarm limits, cabinet location
CCTV coverage analysis per EN 50132-7 — FOV, pixel density at target, NVR storage, bandwidth model
Access control specification per EN 60839-11 — credential types, door controller wiring, UPS sizing
Fire alarm specification per EN 54-14 — detector spacing, zone allocation, cause-and-effect matrix
SCADA architecture per Purdue model — zone boundaries, DMZ, SIS segmentation, conduit schedule
Free tools: CCTV FOV, NVR storage, detector spacing — no signup required
NVR storage and bandwidth model — retention days, compression codec, bitrate per camera
EN 50131 intrusion detection zoning — Grade 1–4, detector spacing, tamper zones, panel sizing
Risk assessment per EN 50131 — threat classification, vulnerability scoring, countermeasure table
Cable schedule export — camera, reader, detector, and lock wiring with conductor sizing
Rack elevation — NVR, access control panel, UPS sizing, patch panel layout
Free Calculators & Tools

Eliminate the documentation grind — focus on system design

1 PDF per discipline, lifetime — 8 disciplines. 3-day free trial · EN/NL/DE/JA/ZH/HI

View Pricing →

FrameAI offers all disciplines as individual plans or bundled in cost-effective packages. View pricing →