DIN EN 1993-1-1 Stahlprofil · Querschnitt von HEM
HEM 100 — Section Properties & EN 1993-1-1 Classification
HEM 100 is a Klasse 1 — Plastisch
Profil in S355 (fy = 355 MPa).
h = 120 mm
b = 106 mm
A = 4,000 mm²
Iy = 1,140 cm⁴
Wpl,y = 238 cm³
EN / NL / DE annexes
Keine Anmeldung · Kostenlos
Querschnittsklassifizierung (DIN EN 1993-1-1 Tabelle 5.2)
Steel Grade
γM0
Web (c/tw )
Flange (c/tf )
Class
S235
1.00
4.67 → 1
1.75 → 1
Class 1
S235
1.10
4.67 → 1
1.75 → 1
Class 1
S235
1.05
4.67 → 1
1.75 → 1
Class 1
S275
1.00
4.67 → 1
1.75 → 1
Class 1
S275
1.10
4.67 → 1
1.75 → 1
Class 1
S275
1.05
4.67 → 1
1.75 → 1
Class 1
S355
1.00
4.67 → 1
1.75 → 1
Class 1
S355
1.10
4.67 → 1
1.75 → 1
Class 1
S355
1.05
4.67 → 1
1.75 → 1
Class 1
S420
1.00
4.67 → 1
1.75 → 1
Class 1
S420
1.10
4.67 → 1
1.75 → 1
Class 1
S420
1.05
4.67 → 1
1.75 → 1
Class 1
S460
1.00
4.67 → 1
1.75 → 1
Class 1
S460
1.10
4.67 → 1
1.75 → 1
Class 1
S460
1.05
4.67 → 1
1.75 → 1
Class 1
Property Value
h (mm) 120
b (mm) 106
tw / tf (mm) 12 / 20
r (mm) 12
A (mm²) 4,000
Iy (cm⁴) 1,140
Iz (cm⁴) 399
Wel,y (cm³) 190
Wpl,y (cm³) 238
iy / iz (mm) 53.4 / 31.6
Bemessungswiderstände · γM0
Resistance Value
Npl,Rd 940 kN
Vpl,Rd 271.4 kN
Mpl,Rd 55.9 kNm
Mel,Rd 44.6 kNm
Resistance Value
Npl,Rd 854.5 kN
Vpl,Rd 246.7 kN
Mpl,Rd 50.8 kNm
Mel,Rd 40.6 kNm
Resistance Value
Npl,Rd 895.2 kN
Vpl,Rd 258.4 kN
Mpl,Rd 53.3 kNm
Mel,Rd 42.5 kNm
Resistance Value
Npl,Rd 1,100 kN
Vpl,Rd 317.5 kN
Mpl,Rd 65.5 kNm
Mel,Rd 52.3 kNm
Resistance Value
Npl,Rd 1,000 kN
Vpl,Rd 288.7 kN
Mpl,Rd 59.5 kNm
Mel,Rd 47.5 kNm
Resistance Value
Npl,Rd 1,047.6 kN
Vpl,Rd 302.4 kN
Mpl,Rd 62.3 kNm
Mel,Rd 49.8 kNm
Resistance Value
Npl,Rd 1,420 kN
Vpl,Rd 409.9 kN
Mpl,Rd 84.5 kNm
Mel,Rd 67.5 kNm
Resistance Value
Npl,Rd 1,290.9 kN
Vpl,Rd 372.7 kN
Mpl,Rd 76.8 kNm
Mel,Rd 61.3 kNm
Resistance Value
Npl,Rd 1,352.4 kN
Vpl,Rd 390.4 kN
Mpl,Rd 80.5 kNm
Mel,Rd 64.2 kNm
Resistance Value
Npl,Rd 1,680 kN
Vpl,Rd 485 kN
Mpl,Rd 100 kNm
Mel,Rd 79.8 kNm
Resistance Value
Npl,Rd 1,527.3 kN
Vpl,Rd 440.9 kN
Mpl,Rd 90.9 kNm
Mel,Rd 72.5 kNm
Resistance Value
Npl,Rd 1,600 kN
Vpl,Rd 461.9 kN
Mpl,Rd 95.2 kNm
Mel,Rd 76 kNm
Resistance Value
Npl,Rd 1,840 kN
Vpl,Rd 531.2 kN
Mpl,Rd 109.5 kNm
Mel,Rd 87.4 kNm
Resistance Value
Npl,Rd 1,672.7 kN
Vpl,Rd 482.9 kN
Mpl,Rd 99.5 kNm
Mel,Rd 79.5 kNm
Resistance Value
Npl,Rd 1,752.4 kN
Vpl,Rd 505.9 kN
Mpl,Rd 104.3 kNm
Mel,Rd 83.2 kNm
Pro feature
Vollständiger Portalrahmen mit 50+ Profilen?
FrameAI Pro verarbeitet Ihren kompletten PDF-Zeichnungssatz — extrahiert alle Profile, klassifiziert jeden Querschnitt, berechnet Knickstäbe und Verbindungen, und generiert werkstattfertige Zeichnungen mit DSTV NC1 Dateien.
Pro-Pläne ansehen →
← ← Zurück zum Rechner
HEM 100 — Querschnittsklassifizierung & Widerstände
Diese Seite zeigt vorausberechnete DIN EN 1993-1-1 Bemessungswerte für das HEM 100 HEM-Profil. Die maßgebende Querschnittsklasse ist 1 (Klasse 1 — Plastisch), die bestimmt, ob das Profil sein volles plastisches Moment entwickeln kann (Klasse 1–2) oder auf das elastische Moment beschränkt ist (Klasse 3–4). Npl,Rd, Vpl,Rd, Mpl,Rd und Mel,Rd sind für alle Kombinationen von Stahlgüte (S235 bis S460) und Nationalem Anhang (EN γM0=1,00, NL γM0=1,10, DE γM0=1,05) angegeben.