EN 1992-4 Anchor Bolt Calculator

Check all EN 1992-4:2018 failure modes for cast-in headed bolts and post-installed bonded anchors — tension: steel §7.2.1.3, concrete cone §7.2.1.4, pull-out §7.2.1.5, splitting §7.2.1.7, blow-out §7.2.1.8; shear: steel §7.2.2.3, pry-out §7.2.2.4, edge failure §7.2.2.5; combined §7.2.3. Group design, NL/DE/BE national annexes. No sign-up.

N_Rd (governing)
54.3kN
V_Rd (governing)
108.5kN
Governing mode
N_Rd,c
Max utilisation
92.2%

Verdict

92.2% PASS ✓

Governing: N_Rd,c — Concrete cone (§7.2.1.4)

Anchor Group Plan — Projected Cone Area

A_c,N c₁ c₂ s₁=200mm Anchor A_c,N cone

Section View — Embedment h_ef & 35° Cone

grout 35° h_ef=200mm A_c,N0 cone

All resistance checks

Mode Clause R_d (kN) E_d (kN) η η bar Result
tension N_Rd,s
Steel failure (tension) §7.2.1.3
653.3 50.0 7.7% PASS
tension N_Rd,c
Concrete cone §7.2.1.4
54.3 50.0 92.2% PASS
tension N_Rd,p
Pull-out / bonded failure §7.2.1.5
326.7 50.0 15.3% PASS
tension N_Rd,sp
Splitting §7.2.1.7
54.3 50.0 92.2% PASS
shear V_Rd,s
Steel failure (shear) §7.2.2.3
392 30.0 7.7% PASS
shear V_Rd,cp
Concrete pry-out §7.2.2.4
108.5 30.0 27.6% PASS
shear V_Rd,c
Concrete edge failure §7.2.2.5
161.3 30.0 18.6% PASS

Combined interaction §7.2.3

Steel: √(β_N²+β_V²) 10.8%
Concrete: β_N+β_V 92.2%

Concrete cone N⁰_Rk,c §7.2.1.4(3)

k_N = 8.9 (cracked) N_Rd,c0 = k_N × √fck × h_ef^1.5 / γ_Mc = 8.9 × √30 × 200^1.5 / 1.5 = 91.92 kN (single anchor) A_c,N0 = (3·h_ef)² = (600 mm)² = 360000 mm² A_c,N = 250000 mm² (group) ψ_s,N = 0.85 ψ_re,N = 1 ψ_ec,N = 1 N_Rd,c = 91.92 × 250000 / 360000 × 0.85 × 1 × 1 = 54.3 kN

Concrete edge failure V_Rd,c §7.2.2.5

k_1,V = 1.7 (cracked) V_Rd,c0 = k_1 × √(fck×h_ef) × c1^1.5 / γ_Mc = 161.28 kN A_c,V0 = 4.5 × c1² = 101250 mm² A_c,V = 112500 mm² ψ_s,V = 0.9 ψ_h,V = 1 V_Rd,c = 161.3 kN

Combined interaction §7.2.3

Steel: √(β_N² + β_V²) = √(0.077² + 0.077²) = 0.108 ≤ 1.0 ✓ Concrete: β_N + β_V = 0.921 + 0.186 = 0.922 ≤ 1.0 ✓