Connections  /  HEA 280  /  S355

Bolted Extended End-Plate Moment Connection

8 bolts Primary dimension
4-row Section
S355 Steel grade
C. Mertens Designer
Ghent, BE Location
← Back to examples

Extended 8-bolt 4-row end-plate connection for HEA 280 beam-to-column moment frame. Column web stiffeners required at tension zone. 8×M24 10.9 preload, Class 4 category per EN 1993-1-8 Table 3.1. Designed for M_Ed = 180 kNm.

Project highlights
Eurocode design summary
EN 1993-1-8 §6.2.7Extended end-plate, 4-row, Class 4
Bolt group design8×M24 10.9, preload Class 1.8
Column web panelV_wc,Rd = 287 kN, γM0=1.0
T-stub in tensionF_T,1-4,Rd = 402 kN per bolt row
EN 1090-2 — Execution classEXC 2
4 downloadable artefacts
DSTV NC1 — CNC data 7th edition ASCII
Download
DXF — Shop drawings AutoCAD R12
Download
IFC — BIM model IFC 4 × 3
Download
PDF — Calculation note EN 1993-1-8 §6.2.7
Download
Calculation overview
Max utilization 74.8%
Bolt preload 215 kN (Class 1.8)
End-plate thickness 30 mm (S355)
Stiffener plate 200×150×10 mm